﻿V705R203C003B005
FIX|CRM20250708032330 issue with DR switch in MCLAG does not processing logic of MAC learning: when MAC migrate from DR to non DR switch

﻿V705R203C003B004
FIX|CRM20250522030882 issue with incorrect meaning of MPLS error message

﻿V705R203C003B002
ADD|CRM20230601014579 add OIDs for power units

V705R203C003B001
FIX|CRM20241231026859 issue with getting IP-addresses from different switch DHCP pools for the same MAC-address in different VLANs

﻿V705R203C003
ADD|ADD new stable FW version

V705R203C002B040
ADD|CRM20241128025864 add commands about fan logs: 'no fan monitor', 'fan monitor'

V705R203C002B039
FIX|CRM20241206026090 add command 'erps node-id priority mode (standard | private)' for changing behavior ERPS NR messages according to G.8032/Y.1344 standard

﻿V705R203C002B038
FIX|CRM20241126025794 issue with loop in EVPN Multihoming-connection

V705R203C002B037
FIX|CRM20250109027108 issue with switch rebooting in the specific case of using SPAN

V705R203C002B036
ADD|CRM20241217026437 add adaptation of MC-LAG and IGMP Snooping for work together

﻿﻿V705R203C002B031
FIX|CRM20241021024585 issue with short-term loop during the MC-LAG establishing

V705R203C002B025
ADD|CRM20240907023555 add support for SNMP, TACACS, Telnet/SSH and info-center via MGMT-interface in VRF

V705R203C002B024
ADD|CRM20240910023617 add command 'logging event link-status include speed-duplex' to check speed and duplex in logs when port goes in UP state

﻿V705R203C002B020
ADD|CRM20240711022165 issue with incorrect DDM information for optical interfaces in some cases

﻿V705R203C002B019
FIX|CRM20240906023531 traffic balance when traffic flows from global to VRF
FIX|CRM20240906023525 issue with short-time loop when one of the MC-LAG partners reboots

﻿V705R203C002B016
FIX|CRM20240829023337 traffic flood in MC-LAG

V705R203C002B015
FIX|CRM20240731022700 issue with mac-learning after dismantle port-group with loopback-detection configured on port


﻿V705R203C002B014
FIX|CRM20240710022137 issue with traffic losses with MC-LAG

﻿V705R203C002B011
ADD|CRM20240409019902 add IP SLA (NQA) function
ADD|CRM20240620021650 add ability to assign MGMT-interface to any VRF

﻿V705R203C002B009
FIX|CRM20240607021322 issue with configuration ip default-gateway

V705R203C002B005
FIX|CRM20240422020181 fix problem with unencrypted keys for some protocols in running-config

﻿V705R203C002B004
FIX|CRM20240424020264 advertised BGP IPv6 routes disappear after some time

﻿V705R203C002B003
FIX|CRM20240403019809 add outputting of prompt for unsupported command

﻿V705R203C002
ADD|ADD new stable FW version

V705R203C001B043
ADD|CRM20240221018870 add ERPS

﻿V705R203C001B042
FIX|CRM20240117018392 issue with incorrect output of SNMP OID (dot1dStpDesignatedRoot) in some cases

V705R203C001B041
FIX|CRM20240204018710 error while deleting VRF in VxLAN environment

V705R203C001B039
ADD|CRM20231201017328 users got incorrect privilege level from MS NPS RADIUS-server

V705R203C001B038
ADD|CRM20231222017886 add route-map features
﻿
V705R203C001B036
FIX|CRM20231013016388 add ability to use VRF forwarding for info-center, SNMP and TACACS functions

﻿V705R203C001B033
FIX|CRM20231113016940 issue with routing EVPN/VxLAN at distributed gateway scheme

V705R203C001B032
FIX|CRM20231128017281 issue with output MAC-address table with filtering by VLAN

﻿V705R203C001B028
FIX|CRM20231009016289 issue with incorrect display state of power 

﻿V705R203C001B027
FIX|CRM20231011016324 issue with privilege level configuration

V705R203C001B026
FIX|CRM20231009016289 issue with terminals freezing in some cases

V705R203C001B025
ADD|CRM20230821015620 added new VSF logs for the issue with VSF stack fall apart

V705R203C001B023
FIX|CRM20230628014920 issue with unavailable VSF stack due SKB leakage in some cases

V705R203C001B022
ADD|CRM20230615014721 add rule-id to ACL

V705R203C001B019
ADD|CRM20230601014578 add function to disable messages about illegal DIP

﻿﻿V705R203C001B016
FIX|CRM20230602014591 BFD static route doesn't disappear from routing table

V705R203C001B015
ADD|CRM20220418009981 add 'archive running-config' functon

V705R203C001B014
FIX|CRM20230516014325 incorrect OSPF working

﻿V705R203C001B013
FIX|CRM20230428014149 fail to config ipv6 ospf network point-to-point

﻿V705R203C001B012
FIX|CRM20230411013951 issue with dst cache overflow in some cases

﻿V705R203C001B011
FIX|CRM20230329013788 issue with USB-port

﻿V705R203C001B010
ADD|CRM20221213012751 add arbitrary UDP-port for syslog

﻿V705R203C001B008
FIX|CRM20230313013556 Switch become unavailable out of cache overflow

V705R203C001B006
ADD|CRM20221216012772 Validity Management of Switch Passwords
ADD|CRM20221220012792 Feature with automatic restart when the switch temperature is too low or too high

V705R203C001B005
ADD|CRM20221216012774 Switch web import SSL certificate

﻿V705R203C001B004
FIX|CRM20230209013216 high cpu utilization due to the inefficient interaction between the switch and CPU

7.6.3.2(R0005.0085)
FIX|CRM20221013012155 issue with BFD on loopback ports

﻿7.6.3.2(R0005.0084)
FIX|CRM20221024012254 issue with radius auth on Windows client

﻿7.6.3.2(R0005.0083)
ADD|CRM20220721011329 An possibility to use more stronger algorithms with 'service password-encryption'
ADD|CRM20220816011606 Add VRRP plaintext authentication

7.6.3.2(R0005.0082)
FIX|CRM20221024012259 issue with copy running config via FTP, SFTP

7.6.3.2(R0005.0081)
FIX|CRM20221020012221 issue with snmpwalk output for snmpv3

7.6.3.2(R0005.0079)
ADD|CRM20220719011297 Adjust the VRF quantity to 1024

﻿7.6.3.2(R0005.0078)
ADD|CRM20211215008619 add command "show vsf config detail" 
FIX|CRM20211207008506 show transceiver detail |load balancing algorithm problem |VSF flow problem